Mounting possibilities

Standard version (h = 22.5 mm)
for mounting on measuring modules withoout riveted
sleeves and springs (e.g. connection head DIN-B)
Connection wires of measuring modules approx. 50 mm long and
insulated.
Fig 7
Mounting the standard version
(Measuring module and transmitter illustrated at a 90° angle)
Z-20017
Attention
Insert the tooth lock washers with their convex edges poin-
ting up. Then tighen up the mounting studs. Pressing the
washers in-between the flange plate of the measuring module
and the bottom of the connection head produces a permanently
solid link-up between the transmitter and the measuring module.
Special version (h = 27.5 mm)
for mounting on measuring module with riveted
sleeves and springs (e.g. connecting head BUSH)
Fig. 8
Mounting the special version
(Measuring module and transmitter illustrated at a 90° angle)
Z-20047
Attention
Use only the supplied threaded screws M3 × 6 mm. The use
of other, longer screws can lead to transmitter damage. In
the case of ex-proof transmitters, this would nullify the
explosion protection.
Standard version (h = 22.5 mm)
Connection head BUZH
Bild 9
Mounting into BUZH head (IP 65, aluminium)
Z-20018
Use the supplied (captive) screws in the connection head to
fix the transmitter.
Standard version (h = 22.5 mm)
Connection head BUKH
Bild 10
Mounting in the BUKH head (IP 65, polyamide)
(here with mounting extension EV, Catalog No. 7957823)
Z-20019
Use the supplied (captive) screws or the mounting extension
EV in the connection head to fix the transmitter.