Herunterladen Inhalt Inhalt Diese Seite drucken

Electrical Connections - V2 VULCAN 24V Bedienungsanleitungen Und Installation

Nicht umkehrbarer elektromechanischer antrieb (unterflurmontage) für flügeltore
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 35

ELECTRICAL CONNECTIONS

VULCAN-230V / VULCAN-120V
Motor cable
DX motor
YELLOW - GREEN
GND
BLUE
COMMON
BLACK
OPENING
BROWN
CLOSING
WARNING: Always connect the earth cable to the
mains power earth system. Use the special fastom shown
in the figure, and a cable with a minimum cross sectional
area of 2.5 mm
2
VULCAN-24V
Motor cable
DX motor
+
BLU
-
MARRONE
ENCODER connection
ATTENTION:For encoder operation, when in the closed
position, both gate panels must rest against a mechanical stop.
Hereafter the directions to follow to connect the cables of the
encoder to the control unit:
CONTROL UNIT
ENCODER cable
DX motor
RED
+ 24 Vdc
M
O
BLACK
COM (-)
T
O
BLUE
FCA2
R
1
WHITE
FCC2
RED
+ 24 Vdc
M
O
BLACK
COM (-)
T
O
BLUE
FCA1
R
2
WHITE
FCC1
CONTROL UNIT
SX motor
GND
COMMON
CLOSING
OPENING
CONTROL UNIT
SX motor
-
+
SX motor
+ 24 Vdc
COM (-)
FCC2
FCA2
+ 24 Vdc
COM (-)
FCC1
FCA1
ATTENTION: extensions of the cables must be made only
with a 4x0,22 shielded cable with polyethylene sheath
ATTENTION: connect the shielding braith sheath to the
common accessories. Check that the ground of the power supply
of the accessories is connected to the common accessories.
11

Werbung

Inhaltsverzeichnis
loading

Diese Anleitung auch für:

Vulcan 120vVulcan 230vVulcan series

Inhaltsverzeichnis