ELECTRICAL CONNECTIONS
VULCAN-230V / VULCAN-120V
Motor cable
DX motor
YELLOW - GREEN
GND
BLUE
COMMON
BLACK
OPENING
BROWN
CLOSING
WARNING: Always connect the earth cable to the
mains power earth system. Use the special fastom shown
in the figure, and a cable with a minimum cross sectional
area of 2.5 mm
2
VULCAN-24V
Motor cable
DX motor
+
BLU
-
MARRONE
ENCODER connection
ATTENTION:For encoder operation, when in the closed
position, both gate panels must rest against a mechanical stop.
Hereafter the directions to follow to connect the cables of the
encoder to the control unit:
CONTROL UNIT
ENCODER cable
DX motor
RED
+ 24 Vdc
M
O
BLACK
COM (-)
T
O
BLUE
FCA2
R
1
WHITE
FCC2
RED
+ 24 Vdc
M
O
BLACK
COM (-)
T
O
BLUE
FCA1
R
2
WHITE
FCC1
CONTROL UNIT
SX motor
GND
COMMON
CLOSING
OPENING
CONTROL UNIT
SX motor
-
+
SX motor
+ 24 Vdc
COM (-)
FCC2
FCA2
+ 24 Vdc
COM (-)
FCC1
FCA1
ATTENTION: extensions of the cables must be made only
with a 4x0,22 shielded cable with polyethylene sheath
ATTENTION: connect the shielding braith sheath to the
common accessories. Check that the ground of the power supply
of the accessories is connected to the common accessories.
11