M
odel can be used witH
e
-H
):
activate the heat pump and set it as necessary for
co
eat
operation (see the relevant manual).
 Proceed with the chosen water treatment.
m
WARNING: read and follow all the instructions related
to the use and storage of chemical products, adhering
strictly to the manufacturer's instructions on the pack-
aging.
m
WARNING! Do not use trichlorine tablets! This may
damage the hot tub components and cause burning or
irritation to the skin and mucous membranes. Any use
of these chemicals voids the manufacturer's warranty.
 Check and as necessary modify the water filtering cycles
based on how you intend to use the hot tub.
Installation of front and side panels
(where included)
 Refer to the corresponding drawings. (

Control panel and functions

0
(
6) All hot tub functions are managed via the control panels on
the tub, as are the respective settings/programming.
NOTE Up/Down button
the key is released, the direction will reverse (when pressing the key,
the display value will decrease) and so on.

Setting the water temperature

The water is heated
with an electrical heater, a heat exchanger or,
alternatively, the Jacuzzi® heat pump. Do not set an excessively
high water temperature, i.e. over the limit of 40 °C. The recommend-
ed temperature is 35-36 °C.
Models equipped with Jacuzzi® Cool Power heat pump have the
water cooling function.
We recommended not to set cooling water temperature too low.
M
odels witH a Heater
tive (see relevant chapter) and, by switching on the pump, the heat-
er turns off (the led relative to the symbol
will be turned on again, if necessary, 10 seconds after the pump
itself is turned off.
w
("
ater teMperature
To check or modify the water temperature, do the following:
J
®
acuzzi
Heat puMp
0
2).
: hold down the key to increase; once
:
if the electric consumption limit is ac-
flashes), the heater
")
set point
(J
®
 Press the "Up/Down"
acuzzi
show the current saved temperature.
 Press the key "Up/Down"
value from a minimum of 15 °C to a maximum of 40 °C (59÷104 °F).
NOTE:
- Press and hold the button down until you reach the desired val-
ue; by releasing the button and pressing it again, the adjustment is
made in the opposite direction.
- In models equipped with a Jacuzzi® EcoHeat heat pump or heat-
er, the temperature can be changed from a minimum of 15°C to a
maximum of 40°C (59-104°F) (check the position of dipswitch no. 6,
please see the "Electrical connections and safety" chapter).
- In models equipped with a Jacuzzi® Cool Power heat pump, the
temperature can be changed from a minimum of 10°C to a max-
imum of 40°C (50-104°F). If it is not possible to set the minimum
value, check the position of dipswitch no. 6 (see chapter "Electrical
connections and safety").
- During operation of the heater, the light spot on the screen next to
the temperature value flashes.
 To show the temperature of the water in the tub again, do
not touch any key for about 5 seconds.
Models equipped with a Jacuzzi® CoolPower heat pump
- The heating is switched off (the filtration pump remains on for 30
seconds) as soon as the water temperature set-point is exceeded
(by about 1 °C), and is not switched on again until the temper-
ature does not drop by about 1.5 °C compared to the set-point.
However, if the water temperature rises to about 1.5°C greater
than the set-point, the Jacuzzi® CoolPower heat pump turns on (wa-
ter cooling, where applicable); the pump will be turned off when the
water temperature drops (approximately 1°C) below the set-point.
If the water temperature continues to drop, at about 1.5 °C
below the set-point, the heater turns on again, according to the
methods described above.
 To ensure precise measurement of the water temperature,
the pump is turned on at low speed (or the filtering pump,
where present), approximately every half an hour for 30 seconds
(even if filtering cycles are not set).
When the system is turned off, or there is a power outage, the last
set point is stored in memory.
When heating is in operation, the LED located under the
bol comes on (if it flashes, this means that heating has been paused,
so as not to exceed the maximum permitted consumption; see the
information at the beginning of the chapter).
CAUTION
m
Do not use the hot tub if the water temperature is 40 °C
or more.
CAUTION
m
Do not use the hot tub if the water has a very low tem-
perature (models with Jacuzzi® Cool Power heat pump).
35