Herunterladen Inhalt Inhalt Diese Seite drucken

GYS GYSPOT INVERTER BP.LG - 220 V Bedienungsanleitung Seite 46

Inhaltsverzeichnis

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

If the caps are not changed after the warning message is displayed and the count is simply reset, they can deteriorate and have a negative
impact on the quality of the weld.
RECORDING FEATURES
The Identification mode is optional and can be activated using the «settings» menu.
If the identification mode is switched off, il suffit de saisir un nom de rapport et de l'activer pour mémoriser les points de soudure effectués.
The log allows to store the parameters of the spots made using the clamp. It is available in all the modes by pressing the 2 buttons
The user program is available in all modes by pressing the
Report (log)
The log created contains: an ID entered by the user, as well as for each spot performed, the tool and arm used, the machine settings (power and
pressure). It also contains the following possible error messages that may have occurred during its recording: I LOW, P LOW, PB CAPS.
The ID is entered using the 4 keys +, -
without deleting the previous ones.
The
button is used to retrieve a previously saved report and read it back on the screen.
The current recording must be stopped by pressing the
report view mode.
To delete the contents of a report, you must
display it on the screen using the button
Identification mode
List of screens used to enter a repair order :
If a repair order has already been created, it cannot be changed or deleted on the machine. To delete it, use the Gyspot software on the PC. The user
can create a maximum of 100 repair orders.
46
GYSPOT INVERTER BP.LG
and
buttons.
Saving a report allows you to retrieve the data of a series of spot made with using the clamp, and to
save them on the memory card so that they can be retrieved from a PC for example. GYS provides
a software called GYSPOT to read the SD card and edit the logs on a PC. This GYSPOT software is
stored on the SD card as well as the user manual.
By default, this feature is disabled when the machine is switched on. Pressing the recording button
(on/off) and the «mode» button starts recording the report in the selected log. Pressing the record
button again (on/off) stops the current recording.
or
. When entering an identifier already in use, the machine will record the new points in succession,
button before it can be displayed on the screen. The
Then press the
button.
The following message appears on the
.
screen.
If the identification mode is set to «ON», all mandatory fields in the repair order must be entered to
allow the weld to go ahead or the machine will display «identification fault».
To activate and deactivate the identification mode, an SD identification card must be inserted in the
BP card reader instead of the SD card containing the programs.
The settings screen is activated by pressing and holding down the
When the SD card «identification» is inserted and «identification ON» is selected, the supervision
screen is displayed.
This screen is used to make the fields «registration, vehicle make, vehicle model, vehicle model,
chassis number» mandatory fields when entering the repair order.
To exit the screen, press the
containing the programs back into the machine card reader.
When the triangle is displayed, a second press
on the
button erases the content of the
report displayed.
The triangle disappears from the screen auto-
matically after 3 seconds.
button for 2 seconds. Then, it is necessary to put the SD card
EN
and
.
button is used to exit the
button for 2 seconds.

Werbung

Inhaltsverzeichnis
loading

Inhaltsverzeichnis