Herunterladen Inhalt Inhalt Diese Seite drucken

Inspection And Servicing; Disassembly - Gemü 536 Original Einbau- Und Montageanleitung

Sitzventil
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

CAUTION
Risk of crushing between
coupling and valve!
Risk of injury.
G
Do not reach into the area of
G
the coupling while the valve
is in operation.
Prior to cleaning or commissioning the
plant:
Check the tightness and the function of
G
the valve (close and reopen the valve).
If the plant is new rinse the piping system
G
with a fully opened valve (to remove any
harmful foreign matter).
Cleaning:
The plant operator is responsible for

selecting the cleaning material and
performing the procedure.
14

Inspection and servicing

WARNING
The equipment is subject to pressure!
® Risk of severe injury or death!
Only work on depressurized plant.
G
CAUTION
Hot plant components!
® Risk of burns!
Only work on plant that has
G
cooled down.
CAUTION
Servicing and maintenance work
G
must only be performed by trained
personnel.
GEMÜ shall assume no liability
G
whatsoever for damages caused
by improper handling or third-party
actions.
In case of doubt, contact GEMÜ before
G
commissioning.
536
Risk of crushing between
coupling and valve!
Risk of injury.
G
Do not reach into the area of
G
the coupling while the valve
is in operation.
1. Use appropriate protective gear as
specifi ed in plant operator's guidelines.
2. Shut off plant or plant component.
3. Secure against recommissioning.
4. Depressurize the plant or plant
component.
The operator must carry out regular visual
examination of the valves dependent on
the operating conditions and the potential
danger in order to prevent leakage
and damage. The valve also has to be
disassembled in corresponding intervals
and checked for wear (see chapter 12
"Assembly / disassembly of spare parts").
Important:
Service and maintenance: Seals
degrade in the course of time. After
valve disassembly / assembly
check that the hexagon nuts a are
tight and retighten as necessary.
15

Disassembly

Disassembly is performed observing
the same precautionary measures as for
installation.
Disassemble the valve (see chapter 12.1
G
"Disassembly of actuator and gasket 43").
Unscrew the control medium lines (see
G
chapter 11.3 "Connecting the control
medium").