6 Operation

6 Operation
NOTICE
• As the ABIDRIVE CW is integrated into a welding system, the operating instructions of the welding
• The ABIDRIVE CW may only be operated by qualified personnel.
6.1 Operating elements
 Fig. 4 Overview of connections and operating elements on page EN-9
Symbol
NOTICE
• The dials (7) and (10) only work in the interval mode.
• The dial scales serve exclusively for orientation with respect to the set values.
6.2 Power supply operating elements
 Fig. 4 Overview of connections and operating elements on page EN-9
Symbol
6.3 Putting into operation
 Fig. 4 Overview of connections and operating elements on page EN-9
1 Switch on the (17) power switch.
2 Open the valve of the shielding gas cylinder.
EN - 14
components, such as welding torch and welding power source, must be observed during operation. In
addition, the safety instructions for the welding process must be observed.
ABIDRIVE CW
Designation
Wire feeder dial (6)
Wire feed rate can be set continuously.
Program selection switch (8)
The following programs can be set: four-stroke, two-stroke, four-stroke interval and two-
stroke interval
Timer / Pause dial (10)
The pause time can be set independently of the wire feeding time.
Timer / Feed dial (7)
The delivery time for the welding wire can be regulated.
Display (9)
The preset wire feed rate is displayed. Changes on the dial (6) are applied the next time
welding is started.
Designation
Power switch (17)
Switching state ON and OFF.
TIG cold wire feeder