Technical data
Vibration:
Voltage insulation:
Insulation resistance:
Dimensions:
Weight:
Testing/certification:
Input data
Rated input voltage:
Power factor correction:
Input frequency:
Efficiency at 230 Vw:
Input current:
Starting current (typical for cold start):
Leakage current:
Output data
Charging voltage:
Retention voltage:
Current:
Charging current:
Rated power:
20
10 to 500 Hz
2 g for 10 min/cycle within 60 minutes for X,
Y and Z axis
I/P – O/P: 3 kVw
I/P – FG: 1.5 kVw
O/P – FG: 0.5 kVw
I/P – O/P: 100 MΩ/500 Vg
see fig. 2, page 4
1.3 kg
230 Vw
> 0.9 (full load)
50 Hz
87 %
1.8 A at 230 Vw
54 A cold start at 230 Vw
< 1 mA at 240 Vw
Lead starter
Absorbed
batteries
glass mat
(AGM)
batteries
14.4 V
14.7 V
13.8 V
13.6 V
max. 25 A
0 – 25 A
360 W
SMP439A
Power supply
13.8 V
13.8 V
EN