Fehlercodes
ODM-Fehlercodes DBM V4
Fehlercode (Definition)
CDBM_E_WRITE_CANT_ ACCESS_DATA
CDBM_E_WRITE_DATA
CDBM_E_WRITE_BSTR_E1
CDBM_E_WRITE_BSTR_E2
CDBM_E_WRITE_CANT_ INTERPRET_ARRAY
CDBM_E_WRITE_VT_ERROR
CDBM_E_WRITE_LENGTH
CDBM_WRITE_ELEMENT
CDBM_MIN_MAX_ERROR
CDBM_TABLE_EXIST
CDBM_MIN_MAX_INVALID
CDBM_DEF_MIN_MAX_INVALID
CDBM_CANT_CHANGE_STRUCTURE_
WHILE_RECORDS_EXIST
CDBM_NEW_STRUCT_NEEDS_TYPE
CDBM_VALUE_ERROR
CDBM_DATATYPE_ UNSUPPORTED_IN_RCS
CDBM_I_COUNT_OF_TABLES_
EXCEEDS_RCS_RANGE
CDBM_I_COUNT_OF_TABLES_
EXCEEDS_OLDDBM_RANGE
CDBM_UNSUPPORTED_DATATYPE_
IN_RCS_MODE
CDBM_WRITE_UNSTRUCTURED_1
CDBM_READ_UNSTRUCTURED_1
CDBM_WRITE_DATA_LENGTH_ INVALID
CDBM_UNKNOWN_VIEW_MODE
CDBM_E_DIAG_TABLE
DTM für EtherNet/IP-Scanner-Geräte | Konfiguration von EtherNet/IP-Scanner-Geräten
DOC061201OI07DE | Revision 7 | Deutsch | 2013-09 | Freigegeben | Öffentlich
Wert
Beschreibung
0XC004C82F
Unable to access SafeArray Data in the
VARIANT
0XC004C830
To write the data of this Element it must be
given as a BSTR, or as an Array of
VT_UI1/VT_I1
0XC004C831
The BSTR string must have an even
length.
0XC004C832
The BSTR string must contain only hex
digits (0..9 and a/A..f/F).
0XC004C833
Unable to interpret data in the SafeArray.
0XC004C834
Data type in the SafeArray is not VT_UI1
or VT_I1.
Data length is invalid for write operation of
0XC004C835
this type.
0XC004C836
Element not found in the Record of the
Table
0XC004C837
Can't write data because of min underflow
or max overflow
0XC004C838
Table already exist in the database
0XC004C839
The Min value is greater than the Max
Value
0XC004C83A
The Default Value is not in the range
between the Min value and the Max Value
0XC004C83B
It's not allowed to change the structure
while Records exist in the Table
0XC004C83C
In a newly added structure the data type
must be set also
0XC004C83D
Range error while validating a value
0XC004C83E
The data type is unsupported in the RCS
file format
0X4004C83F
The count of Tables exceeds the RCS
range of Tables. This can cause problems
(Informational)
if the file is downloaded to RCS Systems
0X4004C840
The count of Tables exceeds the
DBM32.DLL range of Tables. This can
(Informational)
cause problems if the file is used with older
Tools using the DBM32.DLL
0XC004C841
The Data type is not compatible with the
old database format
0XC004C842
The data of an unstructured record can
only be written with the 'Write' Method not
with 'WriteElement'.
0XC004C843
The data of an unstructured record can
only be read with the 'Read' Method not
with 'ReadElement'
0XC004C844
The given data length doesn't correspond
with the expected data length.
0XC004C845
The View Mode is unknown.
0XC004C846
It doesn't make much sense to add or
delete records from a diagnostic table
because those changes are never saved.
144/154