Fehlercodes
Status- & Fehlercodes TCP_IP
Fehlercode (Definition)
TLR_E_TCP_TASK_F_ MESSAGESIZE
TLR_E_TCP_TASK_F_ MESSAGECOMMAND
TLR_E_TCP_TASK_F_
MESSAGECOMMANDRUNNING
TLR_E_TCP_TASK_F_NOT_ INITIALIZED
TLR_E_TCP_TASK_F_BUSY
TLR_E_TCP_TASK_F_ DATABASE
TLR_E_TCP_TASK_F_ DATABASE_READ
TLR_E_IP_ERR_IP_ADDR_
INVALID_IP_CMD_PING
TLR_E_TCP_ERR_IP_ADDR_
INVALID_TCP_UDP_CMD_ OPEN
TLR_E_TCP_ERR_IP_ADDR_
INVALID_TCP_CMD_ CONNECT
TLR_E_TCP_ERR_IP_ADDR_
INVALID_UDP_CMD_SEND
TLR_E_TCP_ERR_IP_ADDR_I
NVALID_TCP_UDP_CMD_ SET_SOCK_OPTION
TLR_E_TCP_ERR_PORT_
INVALID_TCP_UDP_CMD_ OPEN
TLR_E_TCP_ERR_PORT_ INVALID_TCP_CMD_
CONNECT
DTM für EtherNet/IP-Scanner-Geräte | Konfiguration von EtherNet/IP-Scanner-Geräten
DOC061201OI07DE | Revision 7 | Deutsch | 2013-09 | Freigegeben | Öffentlich
Wert
Beschreibung
0xC0080097
The packet length parameter ulLen is
invalid. The correct packet length depends
on the command parameter ulCmd.
0xC0080098
The command ulCmd is unknown.
0xC008009E
The command cannot be executed,
because the previous command is still
running.
0xC00800C8
The task is not initialized.
0xC00800C9
The task is busy (intern).
0xC00800D2
The configuration database is not
available.
0xC00800D4
Error while reading configuration database.
0xC0070100
The IP address parameter ulIpAddr in
command TCPIP_IP_CMD_PING_REQ is
invalid. This means, the IP address
ulIpAddr is equal to the TCP/IP stacks own
IP address.
0xC0080101
The IP address parameter ulIpAddr in
command
TCPIP_TCP_UDP_CMD_OPEN_REQ is
invalid. The parameter ulIpAddr must be
zero (0.0.0.0) or equal to the TCP/IP
stacks own IP address.
0xC0080102
The IP address parameter ulIpAddr in
command
TCPIP_TCP_CMD_CONNECT_REQ is
invalid. The parameter ulIpAddr must be
unequal to the TCP/IP stacks own IP
address.
0xC0080103
The IP address parameter ulIpAddr in
command
TCPIP_UDP_CMD_SEND_REQ is invalid
or doesn't match to the local sub network.
This error occurs, if the IP address is zero
(0.0.0.0) or equal to the address of the
local subnet.
0xC0080104
The parameter ulMulticastGroup (ulMode
= TCP_SOCK_ADD_MEMBERSHIP or
TCP_SOCK_DROP_MEMBERSHIP) in
command
TCPIP_TCP_UDP_CMD_SET_SOCK_
OPTION_REQ is invalid. The parameter
ulMulticastGroup must be a valid Multicast
address. Valid Multicast addresses are
224.0.0.1 ... 239.255.255.255 (224.0.0.0 is
reserved as Base-multicast address).
0xC0080110
The port parameter ulPort in command
TCPIP_TCP_UDP_CMD_OPEN_REQ is
invalid or not available. The parameter
ulPort must be in range 0 ... 65535.
0xC0080111
The port parameter ulPort in command
TCPIP_TCP_CMD_CONNECT_REQ is
invalid or not available. The parameter
ulPort must be in range 1 ... 65535.