Herunterladen Inhalt Inhalt Diese Seite drucken

hilscher DTM Bedienungsanleitung Seite 129

Dtm für ethernet/ip-scanner-geräte; konfiguration von ethernet/ip-scanner-geräten
Inhaltsverzeichnis

Werbung

Fehlercodes
CIP Connection-Manager-Object-Instance Codes zum Erweiterten Status
Allgemeiner
Erweiterter
Status (hexa
Status
dezimal)
0x01
0x0113
0x01
0x0114
0x01
0x0115
0x01
0x0116
0x01
0x0117
0x01
0x0118
0x01
0x0119
0x01
0x011A
0x01
0x011B
DTM für EtherNet/IP-Scanner-Geräte | Konfiguration von EtherNet/IP-Scanner-Geräten
DOC061201OI07DE | Revision 7 | Deutsch | 2013-09 | Freigegeben | Öffentlich
Beschreibung
UDINT
variable
UDINT
variable
1
The value of the Originator to Target and Target to Originator type shall not
both be 0.
OUT OF CONNECTIONS
Connection Manager cannot support any more connections. The maximum
number of connections supported by the Connection Manager has already been
created.
VENDOR OR PRODUCT CODE MISMATCH
The Product Code or Vendor Id specified in the electronic key logical segment
does not match the Product Code or Vendor Id of the target device.
PRODUCT TYPE MISMATCH
The Product Type specified in the electronic key logical segment does not match
the Product Typ of the target device.
REVISION MISMATCH
The major and minor revision specified in the electronic key logical segment does
not correspond to a -valid revision of the target device,
INVALID PRODUCED OR CONSUMED APPLICATION PATH
The produced or consumed application path specified in the connection path does
not correspond to a valid produced or consumed application path within the target
application. This error could also be returned if a produced or consumed
application path was required, but not provided by a connection request.
INVALID OR INCONSISTENT CONFIGURATION APPLICATION PATH
An application path specified for the configuration data does not correspond to a
configuration application or is inconsistent with the consumed or produced
application paths. For example the connection path specifies float configuration
data while the produced or consumed paths specify integer data.
NON-LISTEN ONLY CONNECTION NOT OPENED
Connection request fails since there are no non-listen only connection types
currently open. Refer to Section 3.6 for a description of application connection
types.
The extended status code shall be returned when an attempt is made to establish
a listen only connection type to a target, which has no non-listen only connection
already established.
[Ref.] THE CIP NETWORKS LIBRARY, Volume 1
TARGET OBJECT OUT OF CONNECTIONS
The maximum number of connections supported by this instance of the target
object has been exceeded.
For example, the Connection Manager could support 20 connections while the
target object can only support 10 connections, On the 11th Connection Request to
the target object, this extended status code would be used to signify that the
maximum number of connections already exist to the target object.
RPI IS SMALLER THAN THE PRODUCTION INHIBIT TIME
The Target to Originator RPI is smaller than the Target to Originator Production
Inhibit Time.
Value of Originator to Target RPI that is within the
acceptable range for the application. This field is
defined the same as the RPI parameter in the forward
open request.
Value of Target to Originator RPI that is within the
acceptable range for the application. This field is
defined the same as the RPI parameter in the forward
open request.
129/154