Dip Switches - Interlogix DD1012 Installation Sheet

Vorschau ausblenden Andere Handbücher für DD1012:
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 10
Figure 11
(1) Alarm relay
(2) Alarm zone
(3) Tamper switch output
Setting the detector
See Figure 14 for jumpers and DIP switch location.
Jumpers
Jumpers set onboard EOL mode and value. The circuit is
shown in Figure 11.
JA: Set onboard alarm EOL resistor (Ra)
1 kΩ
4.7 kΩ (factory
default)
Off: No onboard alarm EOL.
JT: Set onboard tamper EOL resistor (Rt)
1 kΩ
4.7 kΩ (factory
default)
Off: No onboard tamper EOL.
Configuring the zone
To set up the zone, apply the following guidelines.
Select appropriate EOL resistor values with JA and JT.
For example, setting of jumper JT determines Rt value.
For isolated outputs remove JT.
Remove jumpers JA and JT to exclude onboard EOL
values.
For a single zone with all onboard resistors set, the zone
resistance can be the following.
Table 2: Zone resistance values
Zone state
Value
0 Ω
Tamper (short)
Normal
Rt
Alarm
Rt+Ra
Tamper (open)

DIP switches

Table 3: SW1, general settings
Switch
Values
6: LED
On: LED on*
5: Remote
On: Remote on
4: Reserved
3: Polarity
On: Positive polarity
P/N 146550999-1 (ML) • REV M • ISS 19AUG19
Ra Alarm EOL resistor
Rt
Tamper EOL resistor
2.2 kΩ
5.6 kΩ
2.2 kΩ
5.6 kΩ
Default
0 Ω
4.7 kΩ
9.4 kΩ
Off: LED off
Off: Remote off*
Off: Negative polarity*
Switch
Values
1, 2: Radar
1 On, 2 On: 12 m (39 ft.)*
range
1 Off, 2 On: 9 m (30 ft.)
*
Factory default
DIP switch SW1
SW1-1, SW1-2: Radar range
Use SW1-1 and SW1-2 to set the radar range exactly to fit the
application. The radar is of a range-gating type which means
that the range of detection is very accurate.
4 m (13 ft.)
6 m (20 ft.)
SW1-3: Polarity
On: Positive polarity. Configures the inputs (WT and D/N) as
"Active high".
Off: Negative polarity. Configures the inputs (WT and D/N) as
"Active low". Factory default.
The functionality is explained in Figure 10.
Figure 10
(1) Polarity high
(2) Polarity low
This function also depends on the SW1-5 setting. See "SW1-5:
Remote functionality" below.
SW1-4: Reserved
Do not change.
SW1-5: Remote functionality
On: Remote on. Enables WT and day/night inputs.
Off: Remote off. Disables WT and day/night inputs (factory
default).
The following functionality depends on the Remote setting.
Table 4: Functions dependent on the Remote setting
Item
Description
SW1-5 Remote on SW1-5 Remote off
SW1-3
Polarity
Selectable
WT
WT input
Enabled
D/N
D/N input
Enabled
Other
Green Mode
Enabled in day
mode with no WT
Alarm memory
Enabled in day
mode with no WT
See also "Connections" on page 4.
SW1-6: LEDs
On: LEDs are enabled. See "LEDs and outputs" on page 6 for
LED functionality.
Off: LEDs are disabled for any state.
1 On, 2 Off: 6 m (20 ft.)
1 Off, 2 Off: 4 m (13 ft.)
9 m (30 ft.)
12 m (40 ft.)
Factory default.
(3) Walk test
(4) Day/night
Positive only
Disabled
Disabled
Disabled
Disabled