Herunterladen Inhalt Inhalt Diese Seite drucken

LORCH MicorStick 160 series Bedienungshandbuch Seite 31

Inhaltsverzeichnis

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 1
Messages
16.2 Error message (ControlPro)
‰ An error code is displayed in the 7-segment display in
the event of a malfunction. The sub-error (Sub-Code)
is displayed by pressing button 16
Code
Error
E01-1
E01-2
Excess temperature
E01-3
E01-4
E02-2
E02-3
UZK overvoltage
E02-4
E02-5
E06-0 Overvoltage
E07-1
EEPROM
E07-2
E09-0 Voltage detection
E12-0 Power unit
E13-1
E13-2
Temperature sensor
E13-3
E14-0
Supply voltage
E14-1
E15-0
Current measurement
E15-1
E18-2 Overload protection
E22-3 Mains undervoltage
E25-0 VRD
E31-4 Communication
E32-1
E32-2
FPGA
E32-4
E33-1
Power unit
E33-2
E34-0
Fan
E34-1
02.16
Cause
Sec. diode was overheated
Primary module was overheated
Transformer overheated
The equipment has been overheated
UZK voltage too high on start-up
UZK voltage too high in DSP
UZK voltage too high in prim. processor
UZK voltage too high in FPGA
Initial voltage too high
EEPROM faulty during initialisation
EEProm access error
Voltage measuring system faulty
Power section start-up faulty
Thermal sensor of sec. diode not ready for operation
Thermal sensor of primary module not ready for
operation
Thermal sensor of transformer not ready for operation
Internal supply voltage too low
Internal supply voltage too low on start-up
Error during current measurement
Error during current measurement FPGA
Safety switch device to protect electrical components
during welding without load
Mains voltage on power unit is too low on start-up
Voltage Reduction Device (VRD) defective
FPGA communication faulty
FPGA overcurrent
FPGA timeout
FPGA IP Max Error
Power unit module not symmetrical
Power unit module not symmetrical on start-up
Fan current too high
Fan current too low
909.2759.9-00
As long as there is an error code on display
i
welding is not possible.
Allow the system to cool
down in standby, check the
ventilation system
Check mains voltage
Contact Service Department
Switch the equipment off and
on again
Contact Service Department
Contact Service Department
Contact Service Department
Check mains voltages
Contact Service Department
Allow the equipment to cool
down in standby
Check mains voltages
Contact Service Department
Contact Service Department
Contact Service Department
Contact Service Department
Contact Service Department
Possible remedy
- 29 -

Quicklinks ausblenden:

Werbung

Inhaltsverzeichnis
loading

Inhaltsverzeichnis