The Orbital or Reciprocating Shaker is built for long, trouble-free, dependable service.
No lubrication or other technical user maintenance is required. It needs no user
maintenance beyond keeping the surfaces clean. However at least every three (3)
months you should:
• Unplug the unit.
• Remove any accumulated dirt from the base and tray.
• Check all accessible items to make sure they are properly tightened.
The unit should be given the care normally required for any electrical appliance. Avoid
wetting or unnecessary exposure to fumes. DO NOT use a cleaning agent or solvent
on the front panel which is abrasive or harmful to plastics, nor one which is flammable.
Always ensure the power is disconnected from the unit prior to any cleaning. If the unit
ever requires service, contact
your VWR
I
U
nTended
se
These Shakers are intended for general laboratory use.
e
d
qUIPMenT
IsPosal
This equipment must not be disposed of with unsorted waste. It is your
responsibility to correctly dispose of the equipment at life-cycle-end by
handing it over to an authorized facility for separate collection and recy-
cling. It is also your responsibility to decontaminate the equipment in case
of biological chemical and/or radiological contamination, so as to protect
the persons involved in the disposal and recycling of the equipment from
health hazards.
For more information about where you can drop off your waste of equipment, please
contact your local dealer from whom you originally purchased this equipment. By
doing so, you will help to conserve natural and environmental resources and you will
ensure that your equipment is recycled in a manner that protects human health.
representative.
e
C
nvIronMenTal
ondITIons
s
M
Tandard
odels
Operating Conditions: Indoor use only.
* For use in dry CO2 environments, incubators, or cold rooms. Not for use in
CO2-incubators with high humidity.
Temperature:
0 to 40°C
Humidity:
maximum 80% relative humidity, non-condensing
Altitude:
0 to 2000 M above sea level
Non-Operating Storage:
Temperature:
-20 to 65°C
Humidity:
maximum 80% relative humidity, non-condensing
Installation Category II and Pollution Degree 2 in accordance with IEC 664.
a
& r
M
dvanCed
eCIProCaTIng
odels
Operating Conditions: Indoor use only.
* For use in dry CO2 environments, incubators, or cold rooms. Not for
use in CO2-incubators with high humidity.
Temperature:
-10 to 60°C
Humidity:
maximum 80% relative humidity, non-condensing
Altitude:
0 to 2000 M above sea level
Non-Operating Storage:
Temperature:
-20 to 65°C
Humidity:
maximum 80% relative humidity, non-condensing
Installation Category II and Pollution Degree 2 in accordance with IEC 664.
* Avoid cold starts: Unit is not designed to start after being in a cold room
environment. Bring unit into cold room from a room temperature environment,
operate and remove unit from cold room as soon as operation is complete.