26
Execution is dependent on standstill recognition (Chapter 7.9, page 26).
NOTE
Taring and entry of a manual tare value is only possible when the function in
the "PARAMETER MENU → FUNCTION KEYS → TARING" is set to ACTIVE.

7.7 Zero on start-up

If this function is activated (parameter menu "SCALE PARAMETERS → PARA-
METER → ZERO ON START-UP"), the unloaded scale is automatically set to
zero when the DWS2103 is switched on (range of zero setting device ±2...20 %).
This takes into consideration the set standstill condition.

7.8 Error displays

The permissible display range depends on the nominal value of the scale and
the set mode of operation (not legal for trade / OIML / NTEP).
MODE ³
LEGAL-FOR-TRADE
NO (not legal-for-trade)
OIML
NTEP
The percentages relate to the nominal weighing range ("NOMINAL VALUE"
parameter)
The following error message appears in the display when the measured value is
outside the maximum display range: −−−−−−−−−−−−−−−−−
Other errors are displayed as a four-digit code with explanation
(e.g. ERROR!
CODE 5700
No standstill
No measured value acquired
They should not occur in normal operation (see also Chapter 10.2, page 29).

7.9 Standstill recognition

The zeroing, taring and printing functions are only executed if the value in the
display is stable. This is known as standstill and is indicated by showing the
unit of measurement. The condition for standstill is that the value changes by
HBM
Lower display limit
−160 %
−2 %
−2 %
DWS2103
Upper display limit
+160 %
Nominal value + 9 d
Nominal value + 5 %