How To Register The Room Regulator In A Particular Zone - Tech Controllers R-8B Handbuch

Inhaltsverzeichnis

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

R-8b
How to register the room regulator in a particular
zone
Each room regulator should be registered in a zone. In order to register, go to the ST-26402
menu and select Sensor in the submenu of a given zone (Zone/Registration/Sensor). After
selecting Registration press PLUS button on R-8b temperature sensor and hold it for about
a second.
If the registration process has been completed successfully, ST-26402 screen
displays an appropriate message whereas the room sensor screen displays "Scs". If the
room sensor displays "Err", an error has occurred during the registration process.
NOTE
Only one room regulator may be assigned to each zone.
The following rules must be kept in mind:
- once registered, the regulator cannot be unregistered, but only switched off in the
submenu of a given zone,
- if the user attempts to assign a sensor to the zone to which other sensor has already
been assigned, the fi rst sensor becomes unregistered and it is replaced by the second one.
- if the user attempts to assign a sensor which has already been assigned to a diff erent
zone, the sensor is unregistered from the fi rst zone and registered in the new one.
It is possible to set individual pre-set temperature value and weekly schedule for each
room regulator assigned to a given zone. The settings may be confi gured both in the main
menu of ST-26402 external controller (Main menu/Sensors) and via www.oeg.emodul.eu
(using ST-507 or 5060). The pre-set temperature may also be adjusted directly from the
room sensor using PLUS and MINUS button.