The output cables should be kept as short as possible and should be positioned together. If possible connect the
work piece to ground in order to reduce the electromagnetic emissions. The operator must check that connecting
the work piece to ground does not cause problems or unsafe operating conditions for personnel and equipment.
Shielding of cables in the work area can reduce electromagnetic emissions. This may be necessary for special
applications.

Technical Specifications

Input Voltage
230 ± 10%
single phase
Reservoir size
Coolant requirement:
Do not use prepackaged welding industry coolants. These
coolants may contain oil-based substances which attack
the plastic components in the pump.
Height
748 mm
Operating Temperature
–10°C to +40°C
RATED OUTPUT AT 40°C
Flow range
MIG
TIG
Open flow
PHYSICAL DIMENSIONS
Width
238 mm
INPUT
Rated current
0,95A
with torch 4,5m: 1,7 ÷ 1,8 l/min
with torch 3,8m: 1,3 ÷ 1,4 l/min
Recommended coolant for COOLARC-25: Acorox
Water or water and pure ethylene glycol mixture can be
used interchangeably.
The glycol % must not exceed 30%.
Length
248 mm
A-7
Frequency
50 Hz
0,5 to 3,3 l/min
3,3 l/min
8,5 l
Weight
17 Kg
Storage Temperature
-25°C to +55°C