FIGURE 3b:
COOLARC-25 Mounting to the Power Source
Diagram
1.
Main Mounting Bracket
2.
Water Hoses Bracket
3.
Blackened Screw B6P 4,8x13
4.
Bolt M6x16 S6K
5.
Plain Washer M6 P/M-82005
Before mounting COOLARC-25 to the power source
firstly you must mount the water hoses bracket. Use
blackened screw B6P 4,8x13 and thread the water
hoses bracket to the power source case, paying
attention to the bracket stamp which must be fit into the
hole bellow the hole for the blackened screw. After
mounting you should hang the water hoses on it. It
allows to arrange water hoses without squeezing or
sharp bends.
Vertical Installation COOLARC-25 on a Power
Source with a Cylinder Undercarriage
For the COOLARC-25 vertically mounted on a power
source with a cylinder undercarriage, you should use the
main mounting bracket. For proper installation, you
should see Figure 3a and Figure 3b. Using provided
blackened screws and proper holes in the cooler case,
fasten the bracket to the cooler back. Then place the
cooler on the undercarriage on its left side. Align the
holes of the cooler bracket with the holes on the rivet nut
in the back of the power source. Using provided bolt
M6x16 S6K and plain washer M6 PN/M-82005 fasten
the cooler bracket to the power source back. After
installation you should check if the connection is firm.
1.
Gas In/Out
2.
to Work
3.
Gas
4.
Power Cable Adapter
5.
Hot Coolant from the Torch
6.
Coolant
7.
Coolant Out
8.
Coolant In
9.
Argon Gas Cylinder
10. Regulator Flowmeter
11. TIG Torch
Water Cooled TIG Torch Connection
7
8
6.
COOLANT
7.
COOLANT OUT
8.
COOLANT IN
12. GUN CABLE
Water cooled MIG gun connection
7
8
13
6.
COOLANT
7.
COOLANT OUT
8.
COOLANT IN
13. AIR
14. PLASMA, CUTTING, POWER SOURCE
15. ELECTRODE CABLE & AIR
Water cooled Plasma system connection
The following should always be observed when
operating the COOLARC-25:
Never operate the cooler with case off.
Immersion in water around electrical lines can
cause electrical shock.
Never place fingers into openings of cooler. Moving
parts can injure.
Unplug the cooler before filling the reservoir.
Never operate the cooler with the reservoir fill cap
off.
Never operate the cooler with the reservoir empty.

Operating Precautions

The following should always be observed when
operating any COOLARC-25 cooler:
Check the reservoir daily.
Keep the reservoir full especially after changing any
water lines.
A-4
FIGURE 4:
6
6
12
FIGURE 5
6
14
15
6
FIGURE 6