Terminals

SW OUT Terminal

The VCR outputs a pulse signal from the SW (switch)
OUT terminal to the camera switcher to control the
switching from camera to camera.
SW OUT terminal
Specify the interval between each pulse signal on the
SW OUT display. Also, set TIMING to FIELD or
FRAME depending on the specifications of the camera
switcher.
Available settings are:
• FIELD: 1, 2, 3, 4, 5, 10, 30, or 50 fields
• FRAME: 1, 2, 3, 4, 5, 10, 30, or 50 frames
1
Press MENU until the SW OUT display appears on
the screen.
<
>
SW OUT
F I ELD
T I M I NG
<
CLOCK ADJUSTMENT
T I ME ADJ.
OPERAT I ON
2
Set the interval by pressing REC/PLAY SPEED +/
– and press SHIFT z.
<
>
SW OUT
F I ELD
T I M I NG
<
CLOCK ADJUSTMENT
T I ME ADJ.
OPERAT I ON
3
Set TIMING to FIELD or FRAME by pressing
REC/PLAY SPEED +/–.
<
>
SW OUT
F I ELD
T I M I NG
<
CLOCK ADJUSTMENT
T I ME ADJ.
OPERAT I ON
36
COM terminal
0 1
F I ELD
>
0 1 : 0 0
I N
0 4
F I ELD
>
0 1 : 0 0
I N
0 4
FRAME
>
0 1 : 0 0
I N
4
When you have completed the settings, press
SEARCH to return to the normal display.

TIMER OUT Terminal

The VCR outputs +12 V from the TIMER OUT
terminal according to the timer setting on the TIMER
SET display. The terminal outputs the signal even if
the timer recording mode is off (the TIMER switch is
set to OFF).
COM terminal
TIMER OUT terminal
Timer starts.

CLOCK SET IN/OUT Terminals

You can set the clock of this unit using an external
switch.
When you use one unit as the master VCR, you can set
the clock of the units connected to the master VCR
using the master VCR.
When Using an External Switch
to CLOCK SET IN
to CLOCK SET OUT
to CLOCK SET OUT
TIMER OUT terminal
12 V
0 V
Timer stops.
External
switch
to COM
to CLOCK SET IN