Specifications - Magnescale LY71 Handbuch

Anzeigeeinheit
Vorschau ausblenden Andere Handbücher für LY71:
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 59

6. Specifications

Function
Display
Display data
Display data at power ON
Display switching
Without comparator
With comparator
Measuring unit input resolution
Display resolution
Input signal
Minimum input phase difference
Calculation
1-axis input
data
2-axis
Without comparator
input
With comparator
Quantization error
Alarm display
Reset
Key operation and external reset
Restart
START key and external input
Preset
Preset/call by key operations, External recall It is possible to store/edit up to three values for each axis.
Master
In combination with a measuring unit with a
calibration
reference point
function
Datum
Datum point set/call by key operations
point
operations
Reference
Reference point hold/relocation by key
point
operations
operations
Hold function Latch input when latch is selected by
general-purpose input, and function
operated by HOLD key
LY71
1-axis input
2-axis input
Description
7 digits and minus display, Color amber
It is possible to set the display data for each axis at power ON.
The display data for each axis can be set by key operations.
The calculation values for each axis can be selected and displayed in the
counter displays A, B and C. (Advanced settings and key operations)
Factory setting : Display A : First axis current value,
Display B : First axis maximum value,
Display C : First axis minimum value
Factory setting : Display A : First axis current value,
Display B : Second axis current value,
Display C : Off (Input axis switching is also possible)
Comparator
: Display A : Data display for axis subject to comparator
display
Display B : Comparator setting value display
Display C : Comparator setting value display
Standard : 0.1 µm, 0.5 µm, 1 µm, 5 µm, 10 µm, 1 s, 10 s, 1 min, 10 min
Expanded : 100 µm, 50 µm, 25 µm, 20 µm, 2 µm, 0.05 µm and 1 degree
can be added.
Measuring unit input resolution or higher and supported inch units
Inch: Basic
: 0.000005", 0.00001", 0.00005", 0.0002", 0.0005"
Inch: Expanded: 0.000002", 0.0001", 0.001", 0.002", 0.005"
A/B quadrature signal, Z signal (Conforms to EIA-422)
100 ns
First axis current value, maximum value, minimum value, peak-to-peak
value (Current value only when using high-speed BCD)
Current value, maximum value, minimum value and peak-to-peak value of
first axis, second axis and addition axis (Each axis can be calculated
individually.)
Current value, maximum value, minimum value and peak-to-peak value of
first axis or addition axis (1 + 2) (Calculation can be performed for only one
axis.)
±1 count
Measuring unit disconnected, Excess speed, Maximum display amount
exceeded, Power failure, Error in stored data
Current value reset, Alarm cancel
Restart of peak value calculation for each axis/all axes
The master calibration value is relocated when going past the reference
point after the power is turned on.
It is possible to store/edit one value for each axis (when not using the
master calibration function).
It is possible to store/edit one value for each axis (when not using the
master calibration function).
Selectable from latch and pause
Latch : Display held while latched (Display hold)
Pause : Peak calculation stopped while paused (Peak calculation hold)
Upper
Lower
19
(E)