Herunterladen Inhalt Inhalt Diese Seite drucken

When Used With The Comparator - Magnescale LY71 Handbuch

Anzeigeeinheit
Vorschau ausblenden Andere Handbücher für LY71:
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 59

2-1-2. When used with the comparator

1
2
4
No.
Name
1
Judgment display
2
ABS lamp
3
Counter display
4
Comparator setting
value display
5
Upper and Lower lamps
6
RESET key
7
Axis Select key
8
Upper Limit Value Input key Used to edit the displayed numerical value
9
CP No. key
(Comparator Number
Switching key)
!
Lower Limit Value Input key Used to edit the displayed numerical value
"
P key
#
key
(Datum Point Value/
Master Calibration Value
Setting key)
$
REF key
%
ABS/INC key
&
SETUP key
(
HOLD key
)
CP.
key
~
±
key
LY71
3
6 7 "
5
8
!9
Function
Comparator judgment display (When NG, the NG lamp at the top
also lights on.)
Lights on : When displaying absolute value (ABS)
Flashes : When selecting the axis
Lights off : When displaying incremental value (INC)
A
: Measurement value display (current value, peak value)
B
: Comparator setting value display
C
: Comparator setting value display
Upper
: Lights on when displaying maximum upper limit value,
flashes when editing
Lower
: Lights on when displaying minimum lower limit value,
flashes when editing
Resets incremental value to zero
Switches to INC mode when pressed during ABS display.
Used to perform operations for counter display A
Used to change the comparator set number
Used to perform numerical value setting operations (preset)
(lamp lights on when selected)
Used to set the datum point (lamp lights on when selected)
Used to set the master calibration value when using the master
calibration function
Used to detect the measuring unit reference point (lamp lights on
when selected)
Used to relocate the master calibration value when using the
master calibration function
Switches between ABS mode and INC mode
Used to start to make various settings
Used when using the hold function (latch/pause)
(lamp lights on when hold function is selected)
Switches the comparator setting values (Used when there is a
higher comparator setting)
Comparator setting value offset input
#
$
%
&
-
.
)
+ ~
2. Name and Function of Each Part
(
/
,
Upper
Lower
3
(E)

Werbung

Inhaltsverzeichnis
loading

Inhaltsverzeichnis