Setting contents
Display
Setting item
Display at
power ON
Display resolution
and polarity
Display axis, and
display data at
power ON
Scaling
Linear
compensation
LY71
Available options
(factory setting)
(Select polarity with
key)
<Expanded selection options
are shown below>
(Factory setting for display A)
(Factory setting for display B)
(Factory setting for display C)
to
(Factory setting
to ±
(Factory setting 0)
<Expanded selection option>
to ±
Remarks
Count display after power ON
display after power ON
(used to detect power supply
interruptions)
(Supports the selected polarity)
0.1 µm
0.5 µm
1 µm
5 µm
10 µm
Angle 1 s
Angle 10 s
Angle 1 min
Angle 10 min
0.05 µm
2 µm
20 µm
25
50 µm
100 µm
Angle 1 degree
* The initial value is the same as
the measuring unit resolution
set by the basic settings.
Displays the current value of the
first axis input
Displays the maximum value of
the first axis input
Displays the minimum value of
the first axis input
Displays maximum value –
minimum value
* To turn off the display, set
. However, you cannot
turn off all the counter displays
at the same time.
Numerically input the
)
magnification.
Numerically input the
compensation value. (Unit: µm)
* Numerical value of measuring
unit resolution
Example: When the measuring
unit resolution is
0.001 mm, the
compensation value
applies to the three
digits below the
decimal point, and
can be set in the
range from –1.000 to
1.000.
4. Settings
15
(E)