3. Installation and Connection
Terminal block connector

Interface cable

Use a shielded cable such as that shown in the figure for the interface cable connected to the terminal block
connector. Connect the shield to the casing near the terminal block connector. In addition, connect the COM
terminal separately from the shield. (This cable should be prepared separately by the customer.)
Cable section
Outer sheathe
Shield
Input signal pin assignment
1
Power supply
2
External reset A
3
External reset B
4
External preset recall A
5
External preset recall B
6
General-purpose input A
7
General-purpose input B
8
General-purpose input C
9
COM

3-4. External contact point outputs

Output circuit

• Output circuit
All output signals are photocoupler outputs (12 V to 24 V 15 mA max.).
To internal circuits
When using the general-purpose output as the reference point output, time until the output signal changes to
High is 200 ms after going past the reference point.
1
OUT A1
2
OUT A2
3
OUT B1
4
OUT B2
5
COM
10
(E)
Apply 12 - 24 V to the (Vcc) input.
(Ex. RESET A)
(Ex. RESET B)
Ex. RCL A
Ex. RCL B
Ex. IN A
Ex. IN B
Ex. IN C
COM
Output signal
Pins 1 to 4
COM
Pin 5
Terminal arrangement
1
2 3 4 5 6 7 8 9
Terminal pin assign
1
2 3 4 5
LY71