3. Installation and Connection

3-1. Installation

Environmental conditions

• Ambient temperature: 0 - 40 °C
• For indoor use (avoid exposure to direct sunlight)
• Install the counter unit so it is protected from coolant, machine oil, chips and the like
• Install the counter unit at least 50 cm from power switchboards, welders, motors and the like
Note
• Do not completely cover the counter unit with a vinyl cover or put it in a sealed case.
• If the counter unit's power is momentarily cut off, or if the voltage temporarily falls below the usable
range, the alarm may sound and faulty operation may occur. If such a situation occurs, unplug the AC
adaptor, wait a few seconds, reinsert the AC adaptor and repeat the operations from the beginning.
Be careful where you install
the counter unit.
Switchboard
(Locate more than 0.5 m away.)
Welder
Panel cut-out diagram
4-R3 or less
Mounting the counter unit from the panel front.
6
(E)
Machine oil
Coolant
Motor
262 ±0.2
+1
246.6
0
Install the counter unit so it is
protected from coolant, machine
oil, chips and the like.
Chips
4-φ5.5
Unit: mm
LY71