5. Key Operations
REF
When not using master
key
calibration function
Axis select key and ENT key operation Valid in reference point mode
Axis select key, datum point key,
numeric key and ENT key operation
External reference point load input
REF
When using master
key
calibration function
Axis select key and ENT key operation Valid in master relocation mode
Hold
Hold function
key
CE key
CP.
key,
CP.
key
±
key
18
(E)
At power ON
During count display
During count
Count display
display
axis
Error display axis Operation prohibited
Valid in reference point mode
During count
Count display
display
axis
Error display axis Operation prohibited
Valid even in other than reference
point mode
During count
Count display
display
axis
Error display axis Operation prohibited
At power ON
During count display
During count
Count display
display
axis
Error display axis Operation prohibited
O
Select from latch and pause.
Latch : Display held while latched (Display hold)
Pause : Peak calculation stopped while paused (Peak calculation hold)
Cancels each input operation partway.
At power ON
During count
When using
display
comparator
When not using
comparator
At power ON
During count
When using
display
comparator
When not using
comparator
Operation prohibited
REF lamp lights on and reference point operation is
enabled (= reference point mode)
(Prohibited when preset lamp or datum point lamp
is lit.)
Reference point hold operation for each axis
(Prohibited when preset lamp or datum point lamp
is lit.)
Reference point load operation for each axis
(Prohibited when preset lamp or datum point lamp
is lit.)
Reference point load operation for each axis
Operation prohibited
REF lamp lights on and reference point operation is
enabled (= master relocation mode)
(Prohibited when preset lamp or datum point lamp
is lit.)
Master calibration function started by reference
point operation → After going past reference point,
operation shifts automatically to datum point setting
mode → Master calibration value stored by setting a
datum point.
Operation prohibited
Switches the comparator setting values
Operation prohibited
Operation prohibited
Differential value input during comparator value
input
Operation prohibited
LY71