Start-up / Operation / Maintenance and Cleaning

Start-up

After the initial commissioning, carefully check all
connections for leaks.
To remove any possible impurities the tap must be
flushed before being used for the first time. To do
this, proceed as follows:
Unscrew the aerator
Open the main water supply and allow the
water to flow for two minutes to flush out any
residues.
Then reattach the aerator

Operation

Note: If the tap has not been used for a long pe-
riod, flush the pipes thoroughly to avoid stagnation
and build-up of residue.
Open the main water supply.
Lift the handle
and swing it to the right or
9
left in order to regulate the speed or tempera-
ture of the water.
Hot water:
Swing the handle
to the left.
9
Cold water:
Swing the handle
to the right.
9
Check operation of the mixer. To do so, swing
the handle
into all permissible positions.
9
Please regularly check the connections are
tight.

Maintenance and Cleaning

Maintaining and
cleaning the tap
Please note that sanitary taps require special care
and attention. Therefore, please follow the instruc-
tions:
8
GB/IE
from the fitting
.
15
1
to the fitting
15
1
When cleaning, never use petrol, solvents,
aggressive cleansers or hard cleaning brushes
etc. These could damage the surface of the
product.
Dry your taps with a cloth after every use in
order to avoid the build-up of any limescale.
Clean the product with a damp, soft cloth and
a mild cleaning agent if required.
Unscrew and remove the aerator
intervals and remove any residues of scale or
foreign bodies.
If heavily contaminated or damaged, replace
.
the aerator
15
Note: The aerator
screwed by hand. Otherwise use an open-end
spanner SW 22 mm and be sure to place a
thin, damp cloth around the aerator
vent damaging it. A pipe wrench with plastic
jaws is also suitable.
Non-observance of the above care advice can be
expected to result in damage to the surfaces of the
product. This will inevitably invalidate the guarantee.

Replacing the cartridge

A cartridge
is a wear part that needs replacing
14
according to the hardness and / or degree of con-
tamination of the water. This becomes evident
when the handle
new cartridges
14
service office.
Note: this step requires an open-end spanner
SW 27 mm or fitting pliers.
Proceed as follows to replace the cartridge
Shut off the main water supply. Allow any
remaining water in the pipework to drain.
Remove the hot/cold plaque
the handle
9
serting a flat object between the edge of the
hot/cold plaque
handle
.
9
Note: Use light pressure to carefully push the
hot/cold plaque
scratch the surface.
at regular
15
.
can normally be un-
15
15
becomes difficult to move. A
9
can be obtained from the listed
by adjusting
11
to the highest position and in-
and the outside of the
11
outward so as not to
11
to pre-
:
14