Remarks and indications
• After transporting the device, wait about 2 hours before its
actuation.
• The fi rst fi lling of cooling space should be performed after its
previous cooling to working temperature. This principle should
be also observed after longer pause in exploitation.
• Do not block any ventilation holes, which would hamper circu-
lation of the cooled air. It is also necessary to ensure proper
airfl ow around the device (aggregate ventilation holes cannot
be covered).
• Keep the condenser clean. Impurities may lead to overheating
of the compressor and as a consequence may result in dama-
ge of the device, which is not covered by warranty.
• Do not use electric devices inside grocery product storing
chamber.
4.1. Temperature regulation
Service of "Igloo" and "Carel" thermostat (temperature regulators) is described in chapter 7 (p.17 and 18)
The basic aim of a thermostat is to control the cooling aggregate to obtain the set temperature within the device
and maintain it within the determined temperature ranges. The producer enters all settings of temperature regula-
tors required for normal functioning of the device. Before primary actuation the user should control and possibly
set the required temperature inside the device on the control panel.
Digital display – displays the current temperature inside the device.
It is forbidden to interfere with systemic parameters of the thermostat, as this can lead to serious consequen-
ces, including the damage of the cooling device!
5. MAINTENANCE
5.1. Cleaning and maintenance
All maintenance services need to be performed after disconnecting the device from power supply!
Protect electric installation against any damage or water spillage
Do not use water stream to clean the device, only a wet cloth
Do not use any sharp objects to remove dirt!
During cleaning the inside of the device do not leave the front glass freely lifted in the aluminium profi le. This
may cause the damage of the glass and is not covered by warranty. Please remove the glass with profi le
for the time of cleaning Fig.10 (p.14).
It is recommended to make a break in the exploitation of the device once a month in order to clean its interior, naturally
defrost the evaporator and clean the condenser.
Do not use mechanical agents in order to fasten the defrosting process!
1
2
3
14
User manual Wiktoria, Wiktoria 2
Fig.10 Front glass during
maintenance of the device
1- Front glass
2- Upper aluminium profi le of the
glass (lifted guide)
3- Lower aluminium profi le of the
glass (catch)
Fig.9 Ventilation holes of the device
DO NOT BLOCK VENTILA-
TION HOLES!!! Minimal distan-
ce between ventilation holes of
the device and other elements of the
equipment (furniture) or walls should
equal at least about 10 cm.
Fig.11 Temperature sensor
inside "Wiktoria 2" device
1
1 – Draining condensate from
evaporator drip rail
2 – Temperature sensor
2
en
www.igloo.pl