2Fitting the actuator

2 Fitting the actuator
Make sure that the combination of actu-
ator and valve body is correct!
▶ Risk of damage to the actuator and
valve body.
For control valves with a reduced
valve seat, make sure that the com-
bination of actuator and valve body is
correct.
Compare the product label of the actu-
ator with the valve body marking.
RXXX
Valve body marking
Actuator product label
1)
RAxxx
1)
RBxxx
1)
RCxxx
RDxxx
RExxx
RFxxx
RGxxx
RHxxx
RJxxx
RKxxx
RMxxx
1) Do not replace the seat seal (regulating needle)
Table 1
For valves that have a reduced valve seat (see table 1), pay
attention to the seat seal in the spare parts kit.
Example:
Valve: 530 15D1137 51 2G1 RD303
Spare parts kit: 530 15SVS 5 2xx RDxx
GEMÜ 514, 530, 532, 534, 550,
554
CAUTION
Valve body marking
R002
R004
R006
R008
R010
R012
R015
R020
R025
R032
R040
2.1 DN 15–50
1. Move the actuator A to the open position.
2. The actuator can be rotated 360°. The control medium
connectors can be in any position.
3. Lubricate the thread of the union nut a using a suitable
lubricant.
4. Place the actuator A on the valve body 1 approx. 90° anti-
clockwise to the end position of the control medium con-
nectors and screw it in hand-tight using the union nut a.
5. Tighten the union nut a with an open-end wrench (see
table below for torques). This rotates the actuator clock-
wise approx. 90° to the desired position.
6. Move the actuator A to the closed position. With the valve
fully assembled, check that it is working correctly and
that it is leak-tight.
Nominal size
DN 15
DN 20
DN 25
DN 32
DN 40
DN 50
Table 2
2.2 DN 65–100
See the operating instructions for the 530 globe valve, sec-
tional view on page 19, for part names.
1. Move the actuator A to the open position.
2. Place the gasket 30 in the valve body 1.
3. Place the actuator A and seat flange 29 on the valve body
1 approx. 90° anticlockwise to the end position of the
control medium connectors.
4. Make sure that the hole patterns of the seat flange 29 and
valve body 1 line up.
5. Tighten the hexagon nuts 6 diagonally.
6. Move the actuator A to the closed position.
7. With the valve fully assembled, check that it is working
correctly and that it is leak-tight.
12 / 16
Actuator size
Torques [Nm]
1G / 1M / 2G / 2M
90
1G / 1M / 2G / 2M /
100
3G / 3M
2G / 2M / 3G / 3M /
120
4G
2G / 3G / 3M / 4G /
120
5G
3G / 3M / 4G / 5G
150
3G / 3M / 4G / 5G
200