Herunterladen Inhalt Inhalt Diese Seite drucken

Assembly Of Actuator - Gemü 695 Originalmontageanleitung

Austausch der ersatzteil-sets sak membrangrößen 25 - 50 dn 15 - 50 steuerfunktion 1
Vorschau ausblenden Andere Handbücher für 695:
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

5.3

Assembly of actuator

1.
Insert spring set comprising
compression springs 7, 8 and 26 into
actuator base 16.
2.
Put on actuator top 10, take care that
the hole patterns of actuator top 10,
actuator membrane 14 and actuator
base 16 are aligned.
3.
Clamp actuator in a press.
CAUTION
Applied pressure too high!
P Risk of breakage of actuator
top 10!
Only use minimum required
¬
pressure.
4.
Bolt together diagonally actuator top 10
and actuator base 16 with bolts 12 and
washers 13.
Important:
The bolts 12 between actuator
top 10 and actuator base 16
are always inserted from
above.
Diaphragm size
25
40
50
5.
Slowly release the press.
6.
Put protective caps 29 onto bolts12.
7.
Screw optical position indicator SA1
into actuator.
8.
Screw in protective cap SA2.
9.
Reinsert loose compressor 3.
10. Reconnect control medium.
Tightening torque
6 Nm
15 Nm
21 Nm
11 / 12