5
Disassembly
5.1
Disassembly of actuator from
valve body
6
Important:
+
After disassembly, clean all parts
of contamination (do not damage
parts). Check parts for potential
damage, replace if necessary (only
use genuine parts from GEMÜ).
1. Disconnect the actuator A from control
medium lines.
2. Undo the hexagon nut 6.
3. Remove the actuator A and seat
fl ange 29 from the valve body 1.
4. Remove gasket 30.
532 SKV
5.2
1. Remove actuator A (see chapter 5.1
"Disassembly of actuator from valve
body").
2. Undo and remove the connecting
bolts 23 between the actuator top 10
and actuator base 25.
A
29
30
3. Remove actuator top 10.
1
16 / 24
Disassembly of actuator top
10
25
23
10