�0 | WBE 4140 | Faults
Faults
Causes
20
1. Pedal pressed during measurement
2. Irregular rotational speed of motor
3. Wheel speed below minimum value
21
The PCB has detected an excessively high wheel speed
with the wheel guard open (shaft rotating at high speed
although the machine has not been started): Power
supply unit is deactivated
22
Irregular measurement sensor signals
29
ATTENTION: the calliper gauge is not in stand-by
position.
30
The measurement arms have been deactivated.
31
The pedal is pressed. Deactivation is in progress.
32
The pedal has been pressed.
33
Incorrect operational system!
34
Re-start the system.
35
Taper calibration error
36
Out of tolerance taper calibration value
37
Check the connection of the Printer
38
Missing Term Text
39
WINCE firmware version incorrect for selected language.
| The selected language will be replaced by English
40
Emergency stop
41
The calliper of the width must be calibrated
|
1 695 655 779
2010-11-9
Remedy
1. Do not press pedal whilst motor is in operation.
2. Make sure the WBE 4140 is not subjected to any
impact during measurement.
3. Check mains voltage (probably too low).
1. Switch off the WBE 4140 .
2. Lower the wheel guard, switch the WBE 4140 on
again without moving the wheel.
3. If the error message persists, contact customer
service.
1. Check that the light barrier PCB is protected
against light and provide a cover if necessary.
2. Check and if necessary replace the light barrier
PCB.
3. Check and if necessary replace the display PCB.
1. Bring the calliper gauge back to stand-by position.
2. Repeat calibration of the electronic calliper gauge.
Calibrate them before reactivating them.
Use a different board.