3. Classification

3 Classification
The transponder is classified as follows:
Explosion Protection Zone
Intrinsic safety
Explosion group
Temperature class
Device group
This applies to areas where a potentially explosive
atmosphere may occur due to gases, vapours or
mist. The information given refers to an ambient
temperature between -20 °C and +40 °C in the
area of use.

4 Emissions

Radio emis-
sions
SRD
RFID (depending on
equipment)
There are no geographical restrictions within the
EU.

5 Declaration of conformity

The company SimonsVoss Technologies GmbH
hereby declares that article TRA.EX complies with
the following guidelines:
10 / 40
EN 60079-11 (Equipment protection by intrinsic
safety "i")
24.50 kHz - 25.06
kHz
13.564 MHz - 13.564
MHz
1
ib
IIC
T3
II2 G
-20 dBµA/m (10 m
distance)
-19.57 dBµA/m (10
m distance)
TRA.EX