COmmISSIONING
Controller menu
Ext. heat generator pump
Can only be adjusted if the "Booster heater" function is activated.
f Activate or deactivate the function.
f
Ext. heat generator pump on/off
Can only be adjusted if the "Ext. heat generator pump" function
is activated.
f Activate or deactivate the function.
f
When the function is activated, the pump starts.
Heating circuit 1 manual mode
f Activate or deactivate the function.
f
Heating circuit 1 circulation pump
Can only be activated if the "Heating circuit 1 manual mode" func-
tion is switched on.
f Activate or deactivate the function.
f
When the function is activated, the pump starts.
Heating circuit 1
Can only be adjusted if the "Heating circuit 1 manual mode" func-
tion is activated.
f Set the output at which the pump should run.
f
Cooling circuit pump on/off
f Activate or deactivate the function.
f
When the function is activated, the pump starts.
Activate manual cooling mixing valve
f Activate or deactivate the function.
f
When this function is activated, the mixing valve is opened.
Mixing valve cooling opening level
Can only be adjusted if the "Activate manual cooling mixing valve"
function is activated.
f Set how far the mixing valve should open.
f
Cooling cylinder diverter valve on/off
f Activate or deactivate the function.
f
When this function is activated, the diverter valve switches.
Disconnect borehole diverter valve on/off
f Activate or deactivate the function.
f
When this function is activated, the diverter valve switches.
Heat surplus diverter valve on/off
f Activate or deactivate the function.
f
When this function is activated, the diverter valve switches.
48
| STE
Pump overheating
f Activate or deactivate the function.
f
Heat surplus fan
f Set the output level at which the cooling fan should run.
f
Heating circuit 2 / 3 / 4 / 5 pump on/off
f Activate or deactivate the function.
f
When the function is activated, the pump starts.
Heating circuit 2 / 3 / 4 / 5 mixing valve opening level
f Set how far the mixing valve should open.
f
DHW draw-off control – pump
f Activate or deactivate the function.
f
When the function is activated, the pump starts.
Opening level, DHW draw-off control – mixing valve
f Set how far the mixing valve should open.
f
DHW draw-off control – booster heater
f Activate or deactivate the function.
f
When the function is activated, the booster heater starts.
DHW heating system – pump unit
f Activate or deactivate the function.
f
When the function is activated, the pump starts.
Opening level, water charging system – mixing valve
f Set how far the mixing valve should open.
f
Pool diverter valve on/off
f Activate or deactivate the function.
f
When this function is activated, the diverter valve switches.
Pool pump on/off
f Activate or deactivate the function.
f
When the function is activated, the pump starts.
Pool mixing valve opening level
f Set how far the mixing valve should open.
f
Manually activate expansion valve
f Activate or deactivate the function.
f
When this function is activated, the expansion valve opens.
www.stiebel-eltron.com