With the myintercom plus IP video door inter-
com, there are different ways to supply power to
your door intercom station and the additional
modules.

3.1. POE

You may use this option with any PoE ready
router or switch or with a PoE injector (IEEE
802.3af-2003 or later).
To connect your door intercom station, please
remove the housing cover and connect the
patch cable to the RJ45 socket provided.
You may also connect the individual cores using
a terminal block: The network is connected
to the terminals marked 1 (orange-white),
2 (orange), 3 (green-white) and 6 (green)
according to EIA/TIA specification 568 B.
Important! To enable tamper protection, the
cover needs to be reattached to the housing
after connection!

3.2. Two-core installation

A second option to supply power to your door
intercom station is using the additional two-
www.behnke-online.de
Instructions myintercom Plus IP video door intercom
core transmitter module. Remove the door
intercom's housing cover and connect a coaxial
cable to the socket provided on the two-core
transmitter. Should you not have a coaxial cable
available and only have the two cores at your
disposal, please use the RF connector provided.
Important! To enable tamper protection, the
cover needs to be reattached to the housing
after connection!
Connect the other end of the coaxial cable to
the two-core receiver. Provide PoE via the patch
cable that is connected to the RJ45 socket of the
two-core receiver. Please use a PoE injector or a
PoE ready router or switch according to the IEEE
802 at standard to do so.
Please note: When using the two-core technol-
ogy, use a separate twisted cable for connection
between 2-core transmitter and receiver. This
cable may not be used to transmit any other
signals or voltages.