5. Use the remaining Tip Seal material to fill the seal
groove on the Scroll Housing and again trim the
excess Tip Seal so that a gap of about 1/8" (3 mm)
remains.
6. Place the new main O-ring onto the Frame (item 10).
Make sure the area where the O-ring sits is clean.
7. Carefully replace the Scroll Housing making sure to
line up the Locating Pins. Be sure that the Tip Seal has
not fallen out of its groove.
1
1. Front Cowling Bolts; M8 (3)
3. Front Cowling
5. Scroll Housing
7. Main O-ring Parker No. 2-168
9. Orbiting Scroll
To test the pump:
1. Run the pump for about 5 seconds. Verify that the
front fan is running.
If you hear loud noises or observe labored operation,
this indicates that the Tip Seal or main O-ring are
possibly out of place.
2. Disassemble and repair as necessary.
The pump is now ready to return to service.
Newly installed Tip Seals may require
NOTE
several hours of run time to seat prop-
erly and enable the pump to meet speed
and base pressure specifications.
24
SH-110 Dry Scroll Vacuum Pump
8
3
Figure 6 Exploded View of Pump Body
8. Reinstall (4) M5 bolts (item 4). Torque the (4) M5 bolts
to 4 N-m (40 in-lbs).
9. Place the front cowling in place and replace the M8
bolts.
10. Reinstall the exhaust valve.
11. Reconnect the pump to the electrical power mains.
5
7
2
6
4
2. Exhaust Adapter (NW16)
4. Frame Bolts; M5 (4)
6. Tip Seals
8. Locating Pins (2)
10. Frame