Herunterladen Inhalt Inhalt Diese Seite drucken

Transport; Maintenance - Parkside PZKS 1500 B2 Originalbetriebsanleitung

Inhaltsverzeichnis

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

Transport/Maintenance
and lower the movable blade guard to
the lower position to cover the flange bolt
(35). Let the release lever (3) move back
to its default position.
• Tighten the cover plate screw with the
4 mm Allen key (e).
• Before continuing your work, make
sure that all safety devices are in good
working condition.
• Important! Every time that you change
the saw blade (6), check to see that it
spins freely in the table insert (9) in both
perpendicular and 45° angle settings.
• Important! The work to change and
align the saw blade (6) must be carried
out correctly.
8.13 Using the laser (Fig. 2/21)
• To switch on: Move the ON/OFF switch
of the laser (31) to the "I" position. A
laser line is projected onto the material
you wish to process, providing an exact
guide for the cut.
• To switch off: Move the ON/OFF switch
of the laser (31) to the "0" position.
8.14 Adjusting the laser (Fig. 21)
WARNING! While adjusting the laser
(e. g. when moving the tool arm),
never actuate the ON/OFF switch (2).
Accidentally starting the power tool can
lead to injuries.
If the laser (13) ceases to indicate the correct
cutting line, you can readjust the laser. To do
so, open the screws (39) and set the laser
by moving sideways to that the laser beam
strikes the teeth of the saw blade (6).

9. Transport

• Tighten mitre lock handle (10) in order to
lock the turntable (15)
• Activate the release lever (3), press
the machine head (4) downwards and
secure with the fastening bolt (30). The
saw is now locked in its bottom position.
• Fix the saw's drag function with the
locking screw for drag guide (25) in rear
position.
• Carry the machine by the transport
carrying handle or hold it by the
recessed handles on the sides of the saw
table.
• When reassembling the equipment
proceed as described under section 7.

10. Maintenance

WARNING! Prior to any adjustment,
maintenance or service work disconnect
the mains power plug!
General maintenance measures
Cleaning
For safe and proper working, always keep
the power tool and its ventilation slots clean.
The retracting blade guard must always be
able to move freely and retract automatically.
Therefore, always keep the area around the
retracting blade guard clean.
Remove dust and chips after each working
procedure by blowing out with compressed
air or with a brush.
Clean the guard roller, automatic extension
fence and turntable regularly.
To clean the laser unit and remove any dust
using a brush.
When cleaning the plastic do not use
corrosive products.
GB / IE / NI
101

Quicklinks ausblenden:

Werbung

Inhaltsverzeichnis
loading

Inhaltsverzeichnis