11. Disposal

For environmental reasons, do not dispose of the device in the household waste at the end of its
useful life. Dispose of the device in accordance with EC Directive – WEEE (Waste Electrical and
Electronic Equipment). If you have any questions, please contact the local authorities responsible for
waste disposal.
Empty, completely flat batteries must be disposed of through specially designated collection boxes,
recycling points or electronics retailers. This is a legal requirement.
The codes below are printed on batteries containing harmful substances:
Pb = Battery contains lead,
Cd = Battery contains cadmium,
Hg = Battery contains mercury.

12. Technical specifications

Cuff pressure
Cuff size
Timing time
Voltage supply for battery operation
Permissible operating conditions
Permissible storage conditions
Permissible transport conditions
Dimensions
Total weight
Protection class
Classification
The serial number is located on the device or in the battery compartment.

13. Mains part

Voltage supply for mains operation
Polarity
Protection class
Notes on electromagnetic compatibility
• The device complies with the EU Medical Devices Directive 93/42/EEC, the German Medical Devices Act (Mediz-
inproduktgesetz) and the European standard EN 60601-1-2 (in accordance with CISPR 11, IEC61000-4-2,
IEC61000-4- 4, IEC61000-4- 5, IEC61000-4- 6, IEC61000-4- 11, IEC61000-4-8) and is subject to particular pre-
cautions with regard to electromagnetic compatibility. The device is suitable for use in all environments listed in
these instructions for use, including domestic environments.
• The device is suitable for use in all environments listed in these instructions for use, including domestic envi-
ronments.
• The use of the device may be limited in the presence of electromagnetic disturbances. This could result in issues
such as error messages or the failure of the display/device.
max. 120 mmHg (when correctly used, as described in
section 7.1.)
29 – 53 cm
10 – 30 minutes with a deviation of ± 10 %
6 V DC (4 x 1.5 V
+5 °C to +40 °C, 15-93 % relative humidity (non-conden-
sing), 700 – 1060 hPa ambient pressure.
-25 °C to +70 °C, 0 – 93 % relative humidity (non-conden-
sing), 700 – 1060 hPa ambient pressure.
-25 °C to +70 °C, 0 – 93 % relative humidity (non-conden-
sing), 700 – 1060 hPa ambient pressure.
Leg cuff: 61 x 67 x 0.5 cm
Thigh cuff: 85 x 23.5 x 0.5 cm
Hand switch: 17 x 7.7 x 3 cm
approx. 1700 g (without mains part)
Type BF
Input: 100–240 V~ 50/60 Hz, 200 mA
Output: 6 V DC, 500mA
22
AA batteries (alkaline type LR06))