Operation Test

● Put through the power supply and then press ON/OFF button on remote contro-
ller to start the unit.
● Press mode button to select auto, cooling, drying, fan or heating function, and
then check if the unit operates normally.
● If ambient temperature is below 16°C, the unit can't operate in cooling mode.

Electric Schematic Diagram

The Electric schematic diagram are subject to change without notice. Please refer
to which one on the unit
DISP2
DISP1
AP2
DISPLAY
BOARD
TUBE TEMP.
ROOM TEMP.
OUTTUBE TEMP.
SENSOR
SENSOR
SENSOR
RT1
RT3
RT2
ROOM
TUBE
OUTTUBE
DISP2
AP1
MAIN BOARD
DISP1
HIGH-WP1
N1 WATER
BK
BK
BU
RD
SA
M2
YEGN
WATER LEVEL
SWITCH
WATER MOTOR
PE
BN(BK)
RECEIVER
BOARD
BU(WH)
AP3
BU
YEGN(GN)
PE
N3
REC
AC-L
K201
COMP.
COMP
R(M)
RD
FAN
RD
M1
YEGN
FAN
MOTOR
RD
BN
C2
PE
CAP.
25
36
87
POWER
L
N
C
YEGN
COMP
S
PE
YE
C1
CAP.
EN