Terminal assignment of the technology applications

5.1
Actuating drive – speed
Terminal
X3
AI1-
AI1+
X5
RFR
DI1
DI2
DI3
DI4
DI5
DI6
5.2
Actuating drive – torque
Terminal
X3
AI1-
AI1+
AI2-
AI2+
X5
RFR
DI1
DI2
DI3
DI4
DI5
DI6
L
Terminal assignment of the technology applications
Assignment (Lenze setting)
Speed setpoint
• ±10 V ≡ ±100 % Motor reference speed (C00011)
Controller enable
Quick stop
Enable speed follower
Invert speed setpoint
Activate fixed setpoint 1 as speed setpoint
Reset error
Enable manual jog via DI7 and DI8:
DI7
DI8
Function
LOW
LOW
Stop
HIGH
LOW
Manual jog in positive direction
LOW
HIGH
Manual jog in negative direction
HIGH
HIGH
- (previous state remains unchanged)
Assignment (Lenze setting)
Torque setpoint
• ±10 V ≡ ±100 % Motor reference torque (C00057/2)
Speed limit value
• ±10 V ≡ ±100 % Motor reference speed (C00011)
Controller enable
Quick stop
Enable torque follower
Invert torque setpoint
Activate fixed setpoint 1 as speed limit value
Reset error
Enable manual jog via DI7 and DI8:
DI7
DI8
Function
LOW
LOW
Stop
HIGH
LOW
Manual jog in positive direction
LOW
HIGH
Manual jog in negative direction
HIGH
HIGH
- (previous state remains unchanged)