5
Commissioning

Status messages of the operating unit

5.3
Status messages of the operating unit
You can always query the status of the keypad and get information about:
The serial interface
ƒ
The name of the loaded driver
ƒ
The version of the loaded driver
ƒ
The network address of the keypad
ƒ
The last error
ƒ
You want to ...
A
query the status of the operating unit.
B
close the status display.
5.4

Status displays on the operating unit

Display
LED red
LED green Power
LED
yellow
82
Press keys ...
On
Bus error
Supply voltage
switched on
Battery
Capacity of the
internal battery
depleted
Example
2x
shift
Port
Driver : CAN Lenze M
Ver
Addr VT: NO ADDR
Error
ENTER : Set Clock / Contrast
Clr
Esc
Off
No communication error Communication error
No supply voltage
Sufficient capacity of
the internal battery
l
: MSP
: 1.01
: NO ERROR
Blinking
on the system bus
(CAN)
EDBPM−H410 DE/EN/FR 4.1