Malfunction of the Drive PLC
Malfunction
Communication error
Communication error
Log-in not possible
PC does not respond
No control signal on the digital
outputs (X2)
No read-in of signals on the
digital inputs (X3)

System error messages

Display
Keypad
n n n n o o o o e e e e r r r r
c c c c c c c c r r r r
C C C C E E E E 0 0 0 0
C C C C E E E E 1 1 1 1
L

Troubleshooting and fault elimination

Abb. 1-24
Cause
Drive PLC has no supply voltage
No connection between PC and Drive PLC
PC system-bus module 2173IB has no supply
voltage
(LED on the PC system-bus module is OFF)
No terminating resistor (120 Ω ) in the system bus
PC system-bus module 2173IB was not initialised
Communication parameter is faulty
The system-bus module was disconnected from
the parallel port (LPT) of the PC during operation
A print job was sent to the interface/port used by
the system-bus module
Missing connection between X1/+24 and X1/O24
HIGH level of input signals is too low (<13 V)
Fault
1)
PC
0
No error
71
System error
61
Communication error to AIF
62
Communication error to
CAN-IN1 with sync control
Remedy
Switch on supply voltage
Check system bus wiring
Instructions for the PC system bus module
2173IB
41
Plug in the supply voltage adapter for the DIN/PS2
keyboard connection
Instructions for the PC system bus module
2173IB
36
Follow the switch-on sequence:
1. Plug the PC system-bus module 21731B into
LPT1 or LPTx
2. Switch on the PC
Set the communication parameter correctly
DDS "Getting started", chap. 4.4.2
Restart the PC
Restart the PC, and use the other parallel port
(LPT) for printing
Set up the connection
39
HIGH levels of the input signals must amount to
13 V ... 30 V
39
Cause
-
Strong interference on control
cables
Ground or earth loops in the wiring
Faulty transmission of control com-
mands via AIF
CAN-IN1-object receives faulty data
or communication is interrupted
EDK10200EV3 DE/EN/FR 6.0
Remedy
-
Shield control cables
Insert the communication module
into the hand terminal
Check the plug connection of bus
module
FIF
Check transmitter
Increase monitoring time under
C0357/1 if necessary
?