Herunterladen Inhalt Inhalt Diese Seite drucken

Troubleshooting - Klarstein Pasadena Handbuch

Gas-räuchergrill
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

TROUBLESHOOTING

Problem
Gas leaking from
cracked/cut/
burned hose
Gas leaking
from LP tank
Gas leaking from
LP tank valve
Gas leaking between
LP tank and regula-
tor connection
Fire coming through
control panel
Grease fire or
continuous exces-
sive flames above
cooking surface
Possible Reason
Damaged hose
Mechanical failure due
to resting or mishandling
.Failure or tank valve
from mishandling or
mechanical failure
Improper installation,
connection not tight,
failure of rubber seal
Fire in burner tube
section of burner due
to partial blockage
Too much grease
buildup in burner area
Solution
Turn off gas at LP tank,
if hoes is cut or cracked,
replace hose.See LP tank
lead test and connection
regulator to the LP tank
Turn off LP tank valve
Turn off LP tank valve. Re-
turn LP tank to gas supplier
Turn off LP tank valve,
remove regulator from
cylinder and visually
inspect rubber seal for
damage, see LP tank
test and connection
regulator to the LP tank
Turn off control knobs
and LP tank valve.
After fire is out and grill
is cold, remove burner
and inspect for spider
nests or rust. see natural
hazard and cleaning the
burner assembly pages.
Turn off LP Tank. Leave lid
open to allow flames to
die down. After cooling,
clean food particles
and excess grease from
inside firebox area,
grease cup/pan/tray,
and other surfaces
EN