Herunterladen Inhalt Inhalt Diese Seite drucken

Gluing On Sealing Bands; Installing Slide-In Module Ppb 30 O/K/Rc With Extension Duct - Maico PPB 30 K Montageanleitung

Endmontage-set für pushpull lüftungssysteme
Vorschau ausblenden Andere Handbücher für PPB 30 K:
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

UK | 9 Mounting
Mo
CAUTION
!
Danger of injury when handling housing
parts with sharp edges, e.g. burrs. Wear
protective gloves.
9. Saw extension duct to "x" + 5 mm.
Deburr saw cut.

9.4 Gluing on sealing bands

1. Glue sealing band [3.1] and [7] onto out-
side of duct end of fluid separator [3]
and/or onto outside of extension duct [5]
so that it terminates flush at the face end.
NOTICE
Damage to brickwork caused by conden-
sate if the sealing bands [3.1] and [7] are
fitted incorrectly. Glue in sealing bands
correctly.
9.5 Installing slide-in module
PPB 30 O/K/RC with extension duct
1. Produce fixing holes for the internal cover.
Use enclosed drilling template. Note the
TOP unit position. Insert dowel.
2. Slide extension duct [5] into wall sleeve
with centring ring(s) [4] and if necessary
[6] up to stop of external cover. Ensure
that the centring ring is positioned as far
38
inside as possible. If needed, fix centring
ring on wall sleeve with adhesive tape.
With PPB 30 VS extension, use two cen-
tring rings. The sealing band [7] must fit
tightly in the external cover.
3. Remove electronics compartment cover
(2 screws).
4. Use thin screwdriver to pierce cable grom-
met in internal housing.
NOTICE
Damage to unit from water ingress if the
connecting cable is incorrectly fed into
the internal housing or if the cable grom-
met is not fitted correctly. Pierce cap of
cable grommet [13] so that it can tightly seal
the power cable. The cable grommet must
be correctly attached in the housing.
If using PPB 30 K units and connecting
an optional button or switch, the second
input is used with the relevant grommet
 Figure.
5. Slide complete slide-in unit a little into the
wall sleeve with the internal cover. Guide
connecting cable(s) through cable grom-
met(s) into connection area.
6. Slide complete slide-in unit into the wall
sleeve with the internal cover until stop is
reached. Sealing band [3.1] must fit tightly
in extension duct.
7. Screw internal cover down to wall with 4
screws. Note the TOP unit position. Suita-
ble mounting material is to be supplied by
the customer.