Indoor Unit Maintenance
Part
Outdoor fan
To check the noise level
1.
Outdoor condenser
2.
Compressor
Compressor running noise and vibrations
1.
Electrical Part
2.
3.

4 Safety instruction

4.1 Safety notice items:

User qualification
This appliance is not intended for use by persons (including children) with reduced physical, sensory or mental capabilities, or lack of
experience and knowledge, unless they have been given supervision or instruction concerning use of the appliance by a person
responsible for their safety.
Children should be supervised to ensure that they do not play with the appliance.
When units are operating
Do not use any sharp article to press the bottom of controller;
Do not twist and pull the cable of controller;
Do not use any chemical detergent to clean the wiring controller;
Do not put any barrier between the inlet and outlet of air both indoor and outdoor units;
When units are in failure
Do not repair by yourself, contact with the local service agents for help;
If the wiring controller or remote controller show the malfunction code, contact with the local service agents for help;
If any refrigerant leakage is found, stop the units and call the local service agents for help, and keep the inside room ventilated;
Long time not use the air conditioning
To use the units again after a long time no usage of air conditioning, to run units in fan mode for 4~5 hours,
To shut off the power, do not the unit is in standby status;
When restart the units, please power on 12 hours in advance and let unit in standby status;
To relocate the unit
To reinstall or move the units to other place, contact with the local service agents for help;
Improper installation will cause power leakage and fire disaster;
Improper installation will cause refrigerant leakage and hurt of human being and environment;

4.2 User instruction

Before using the digital scroll unit, the user must know the followings:
Cooling mode, temperature range : Indoor 15~24°C (WB), Outdoor 0~43°C (DB) .
Heating mode, temperature range : Indoor 15~27°C (DB), Outdoor -15~16°C (WB) .
Refer to the indoor controller manual to know how to control the indoor unit operation mode;
If user can not solve the failure problem, contact with the local service agents for help;
Please keep the children away from the units
Only professional technician can do the installation , maintenance and reparation;
Both indoor and outdoor units power shall be supplied independently , shut off the main power switch before any maintenance;
When select outdoor units, do the selection properly ;
To prevent the inference of TV , radio and audio
Do not put any article at location of air inlet and outlet of indoor units;
Maintenance Checking step
To clean the dirt of fins
To remove any barrier which inhibit the air flow
To check the running ampere and voltage is normal or not
To check the electrical connection is fixed or loose
To check the controller in normal working conditions