TroUblesHooTInG

Error/Problem
The
leD (22) will light
up�
leD
(21) will light up�
battery cannot be charged
long charging time
battery voltage too low
cleanInG, care
anD MaInTenance
Caution!
Caution! Risk of electric shock. Always first unplug the
230 V power plug (5)�
clean clamps after every charging� To prevent corro-
sion, wipe off any battery fluid which may have come
into contact with the clamps�
carefully wind the cable when storing the device� This
will help prevent accidental damage to the cable and
the device�
clean the product with a soft, dry cloth�
store the machine in a clean, dry place�
Caution!
Only qualified technical personnel should change the
plug or the connecting cables� This will guarantee the
safety of the device is maintained� If the product is no
longer suitable for use dispose of it in an environmen-
tally friendly manner in accordance with your local
ordinances�
Possible cause
Defective battery:
battery voltage is under 1�5 V
battery incorrectly/not connected
no power supply, charger not plugged in�
only a very low charging current is used
in very low temperatures (below 0 ºc)�
This will extend the charging time� as the
battery warms up, the charging current is
adjusted accordingly�
battery capacity too high for the charger
being used�
battery wasn't charged long enough�
English 31
Correction
Have the battery checked by a speciality
repair shop�
replace battery�
Unplug charger and check the connections�
Verify the charger is plugged into a 230 V
mains outlet and the "Power" leD is on�
battery may be defective
charge battery in normal conditions�
explosion hazard!
never charge frozen batteries�
Use a suitable charger�
ensure the battery is charged long enough�