Technical Data
Inverter Size
Housing size
Phases
Output nominal power
Max. rated motor power
Output nominal current
Max. short time current
OC-tripping current
Nominal input current
Max. permissible mains fuse (inert)
Rated switching frequency
Max. switching frequency
Power loss at nominal operating
Stall current at 4kHz
Stall current at 8kHz
GB
Stall current at 16kHz
Max. heat sink temperature TOH
Motor line cross section
Min. braking resistor
Typ. braking resistor
Max. braking current
Overload curve (page appendex)
Tightening torque for terminals
5)
Mains voltage
Mains frequency
Output voltage
Output frequency
Max. shielded motor line length
Storage temperature
Operating temperature
Model / protective system
Relative humidity
EMC tested according to
Vibration/Jolt according to
Climatic category
1)
With the regulated systems F5-M as well as F5-S 5% are to be subtracted as control reserve.
2)
Max. current before the responding of the OL2-function (only F5-M; F5-S; F5-A)
3)
Recommended minimum cross section of the motor wire for rated power and a cable length of upto 100m (copper)
4)
This data is only valid for units with internal brake transistor GTR 7 (see "unit identification")
At mains voltage ≥460V multiply the nominal current with factor 0,86.
5)
GB - 14
[kVA]
[kW]
[A]
1)
[A]
[A]
[A]
[A]
[kHz]
[kHz]
[W]
2)
[A]
2)
2)
[°C]
3)
[mm²]
4)
[Ohm]
4)
[Ohm]
[A]
[Nm]
[V]
[Hz]
[V]
[Hz]
[m]
[°C]
[°C]
25
26
U
U
3
3
145
173
110
132
210
250
263
313
315
375
231
275
315
400
4
4
8
8
2300
2800
210
250
168
162,5
-
90
95
120
4
4
4,3
4,3
200
200
2
25
305...500 ±0 (400 V Nominal voltage)
50 / 60 +/- 2
3 x 0...U Mains
see Control board
50
-25...70 °C
-10...40 °C
IP20
max. 95% without condensation
EN 61800-3
-
3K3 in accordance with EN 50178
27
U
3
208
160
300
375
450
330
450
2
8
3100
240
180
150
4
4,3
200