Herunterladen Inhalt Inhalt Diese Seite drucken

KEB COMBIVERT F5-B Betriebsanleitung Seite 28

Vorschau ausblenden Andere Handbücher für COMBIVERT F5-B:
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 3
Technical Data
Inverter Size
Housing size
Phases
Output nominal power
Max. rated motor power
Output nominal current
Max. short time current
OC-tripping current
Nominal input current
Max. permissible mains fuse (inert)
Rated switching frequency
Max. switching frequency
Power loss at nominal operating
Stall current at 4kHz
Stall current at 8kHz
Stall current at 16kHz
GB
Max. heat sink temperature TOH
Motor line cross section
Min. braking resistor
Typ. braking resistor
Max. braking current
Overload curve (page appendex)
Tightening torque for terminals
5)
Mains voltage
Mains frequency
Output voltage
Output frequency
Max.shielded motor line length
Storage temperature
Operating temperature
Model / protective system
Relative humidity
EMC tested according to
Vibration/Jolt according to
Climatic category
1) With the regulated systems F5-M as well as F5-S 5% are to be subtracted as control reserve
2) Max. current before the responding of the OL2-function (only F5-M; F5-S; F5-A)
3) Recommended minimum cross section of the motor wire for rated power and a cable length of upto 100m (copper)
4) This data is only valid for units with internal brake transistor GTR 7 (see "unit identification")
5) At mains voltage ≥460V multiply the nominal current with factor 0,86.
GB - 10
[kVA]
[kW]
1)
[kHz]
[kHz]
[W] 350
2)
2)
2)
[°C]
3)
[mm²]
4)
[Ohm]
4)
[Ohm]
[Nm]
[V]
[Hz]
[V]
[Hz]
[m]
[°C]
[°C]
14
15
E
G
G
3
3
13
19
7,5
11
[A]
33
48
[A]
49,5
72
[A]
59
86
[A]
43
63
[A]
50
80
4
16
8
16
16
410
460
430
[A]
33
36
36
[A]
24
33
-
[A] 16,8
26
-
10
25
16
8
8
20
13
[A]
25
50
50
1,2
2,5
180...260 ±0 (230 V Nominal voltage)
100
max. 95% without condensation
Germanischer Lloyd; EN 50155
3K3 in accordance with EN 50178
16
17
18
H
H
R
R
3
3
3
26
33
40
15
18,5
22
66
84
100
99
126
150
119
151
180
86
92
116
80
100
160
16
16
8
8
16
16
16
8
550
850
1020 1200 1350 1620
53
72,5
92
110
53
72,5
84
100
53
66
50
-
90
25
35
50
5,6
5,6
4,7
4,7
10
7
5,6
70
70
85
85
1
4
50 / 60 +/- 2
3 x 0...U Mains
see Control board
-25...70 °C
-10...45 °C
IP20
EN 61800-3
19
20
21
R
R
R
3
3
3
46
59
71
30
37
45
115
145
180
172
217
270
206
261
324
126
165
198
160
200
315
8
8
8
8
8
8
126
159
198
115
145
180
-
-
-
50
95
95
3,9
2
2
4,7
3,9
3,0
102
160
160
6
50
-

Werbung

Inhaltsverzeichnis
loading

Diese Anleitung auch für:

Combivert f5-sCombivert f5-gCombivert f5-m

Inhaltsverzeichnis