DMX operation

Setting the DMX starting address
For operation with a controller with DMX512 protocol, the device is equipped with 5 control channels. To be
able to operate the device with a DMX controller, the DMX starting address must be set. The starting
address depends upon which DMX controller is being used. Please refer to the controller's documentation.
1
Press the MODE button so many times until "DMX512" is indicated in the display. Confirm with the
ENTER button.
2
Use the buttons UP and DOWN to set the address. Confirm with the ENTER button.
3
Press the button MODE in order to return to the main menu.
4
The display lights up normally when DMX signals are being received. If no control signals are available,
the display will flash.
Note: Please make sure that you do not have any overlapping channels in order to control each device
correctly and independently from any other fixture on the DMX chain. If several devices are addressed
similarly, they will work synchronically.
Functions in DMX mode
Channel 1 – Warm white
Value
000 – 255
Channel 2 – Cold white
Value
000 – 255
Channel 3 – Dimmer
Value
000 – 255
Channel 4 – Strobe
Value
000 – 009
010 – 255
Channel 5 – Dimmer speed (step response)
Value
000 – 063
064 – 127
128 – 191
192 – 255
Warm white (0=off, 255=100% warm white)
Cold white (0=off, 255=100% cold white)
0 – 100 % dark > bright
No function
0 – 100 % slow > fast
Response characteristics of LEDs
Response characteristics of halogen lamps, fast
Response characteristics of halogen lamps, middle
Response characteristics of halogen lamps, slow