Connector cable of the incremental encoder simulation at socket X3B
Socket X3B (Servo/FI 1)
5
2.3

Start-up

After the installation or exchange of an encoder interface some adjustments of the inverter/
servo software have to be done before operation:
• Switch on inverter
• Select application mode
• Select parameter Ec.10 and control whether value „2: Incremental encoder output" is
entered. The displayed value has to be confirmed by „ENTER" in any case.
• The increments per revolution of channel 1 (parameter Ec.1) determine the increments per
revolution of the simulation.
• Select parameter Ec.20 and adjust channel 2 with Bit 0 to output.
• Select parameter Ec.27:
adjust the source for the simulation with Bit 0...1
0:
1:
2:
determine resolution with Bit 2...4, if Bit 0...1 = „2"
0:
1:
2:
3:
adjust divisor for division of the increments per revolution with Bit 5...6
0:
1:
2:
4
3
2
1
9
8
7
6
GND
A+
1
A -
6
B+
2
B -
7
N+
3
N -
8
COM
9
Channel 1
Channel 2 (no function at the moment)
Actual value (ru.7, if no encoder is connected on channel 1)
256 inc./revolution
512 inc./revolution
1024 inc./revolution
2048 inc./revolution
1 (direct)
2
4
Connect-up
external shield at
the respective
connector housing
Socket X3B (Servo/FI2)
1
2
3
4 5
GND
1
A+
2
A -
3
B+
4
B -
5
N+
6
N -
8
COM
6
7
8
Core colour
green
yellow
blue
red
gray
pink
white
13