Anzeigen im Bedienfeld
Anzeigeleuchten
Constant
Flashing
Flashing
Constant
Constant
Constant
Constant
Flashing
Constant
Constant
Constant
Flashing
Flashing
Constant
Flashing
Flashing
Constant
Constant
Original instruction
Ursache
The appliance is ready for operation
Water tap closed or water shortage
Detergent tank empty
Machine scaled
Machine has run for more than 120 s
without propper water supply. Machine
shuts down to avoid pump overheating.
Low descaling additive
.
1)
Machine is still operational.
Service interval has expired.
Machine is still operational.
Service interval due in 20 hours.
Machine is still operational.
Boiler overheated. Exhaust sensor
(EXT-H) has cut off fuel supply.
Machine scaled
Boiler not serviced
Cold water operation is possible
Flame sensor (B7) is sooted
Ignition or fuel system failure
Cold water operation is possible
Boiler is over sootet and needs service
Boiler is filled with diesel
Temperature sensor shorted
Temperature sensor is disconnected
Cold water operation is possible
Flow sensor fault
98
Abhilfe
Check water supply
Refill detergent or set Detergent knop
to "0"
STORCH Service
Restart machine, if fault continues.
STORCH Service
Check descaling additive level and refill.
STORCH Service
STORCH Service
STORCH Service
Clean flame sensor (B7)
(look to H6 in the drawing)
STORCH Service
STORCH Service
STORCH Service
STORCH Service