3-8. Setting the hysteresis

The hysteresis can be set using option switches 3 to 5 (switch
for hysteresis per unit resolution and hysteresis 1 and 2
switches). Improvement can sometimes be gained by raising
the hysteresis value when the number of divisions is large
with respect to the input signal accuracy or when flickering
of the A/B phase signals occurs due to noise or other adverse
conditions.
In the default settings, the hysteresis for 1/number of divisions
is disabled, and the hysteresis setting value is 1-cycle/2048.
OPTION switch 3
(switch for hysteresis
per unit resolution)
ON
OFF
In the default setting, the hysteresis for 1/number of divisions
is OFF.
24 (E)
Hysteresis for 1/number
of divisions
Hysteresis for 1/number
of divisions: Enabled
Hysteresis for 1/number
of divisions: Disabled
OPTION switch 4
OPTION switch 5
(hysteresis 1)
(hysteresis 2)
ON
OFF
ON
OFF
n
The return error increases as the hysteresis amount gets larger.
Hysteresis amount
ON
1 cycle/8192
ON
1 cycle/4096
OFF
1 cycle/2048
OFF
1 cycle/1024